The P5 error on your LG Dryer means there is a communication failure between the main control board and the motor control board. This error typically requires resetting the dryer or checking internal wiring connections to restore proper communication.
| Error code | P5 |
|---|---|
| Meaning | Communication error between main PCB and motor control board |
| Severity | Medium — Dryer will not operate until resolved |
| Time to fix | 5–45 minutes |
| Tools needed | Screwdriver, multimeter (for advanced diagnostics) |
What the P5 error means
The P5 error code indicates a communication breakdown between your LG dryer’s main control board and the motor control board (also called the inverter board). These two circuit boards need to exchange signals continuously for the dryer to operate properly. When this communication fails or becomes interrupted, the dryer displays the P5 error and will not run a cycle. This can be caused by loose connections, damaged wiring harnesses, or in some cases, a failing control board.
Common causes
- Loose or disconnected wire harness between control boards
- Power surge or electrical interference disrupting board communication
- Corroded or damaged wiring connections
- Faulty main control board (PCB assembly)
- Failed motor control board or inverter board
- Temporary system glitch requiring a power reset
How to fix the P5 error
- Perform a hard reset: Unplug the dryer from the wall outlet (or turn off the circuit breaker) and wait 5 minutes. This allows the control boards to fully discharge and reset. Restore power and test if the error clears.
- Check the wire harness connections: Unplug the dryer and remove the top and front panels to access the control boards. Locate the wire harness connecting the main control board (usually behind the control panel) to the motor control board (typically mounted near the motor). Disconnect and firmly reconnect all harness connectors to ensure proper contact.
- Inspect wiring for damage: Examine all wires in the harness for signs of damage, burns, corrosion, or pinching. Look particularly at connection points and areas where wires might contact sharp edges. Replace any damaged wire harnesses.
- Test the main control board: If connections are secure and undamaged, the main control board may be faulty. Check for visible burn marks, swollen capacitors, or other damage. If found, the main PCB assembly will need replacement (part numbers vary by model).
- Test the motor control board: Similarly inspect the motor control board for visible damage. If the main board appears fine but the error persists, the motor control board is likely the culprit and should be replaced.
- Contact a professional technician: If you’re uncomfortable working with electrical components or the error persists after checking connections, contact an LG-certified appliance repair technician. Control board diagnosis and replacement requires technical expertise.
FAQ
Can I reset the P5 error code without opening my LG dryer?
Yes, start with a simple power reset by unplugging the dryer for 5 minutes. This resolves the P5 error in many cases where it’s caused by a temporary communication glitch. If the error returns immediately or after one cycle, you’ll need to inspect internal connections.
How much does it cost to fix a P5 error on an LG dryer?
If a simple reset fixes it, there’s no cost. A service call to check connections typically costs $100–$200. If a control board needs replacement, expect $150–$300 for the main control board or $200–$400 for the motor control board, plus labor costs of $100–$200.
Is the P5 error covered under my LG dryer warranty?
LG dryers typically come with a 1-year parts and labor warranty, with extended coverage (up to 10 years) on the motor and drum. If your dryer is within the warranty period, control board failures are usually covered. Check your purchase date and contact LG customer service at 1-800-243-0000 to verify coverage.